致力于世界電聲科技

        MLT-5025 - 貼片蜂鳴器

        A. SCOPE 
        This specification applies magnetic buzzer, MLT-5025

        B. SPECIFICATION

        No.

        Item

        Unit

        Specification

        Condition

        1

        Oscillation Frequency

        Hz

        4000

        Vo-p=1/2duty , square wave

        2

        Operating Voltage

        Vo-p

        2 ~ 4

         

        3

        Rated Voltage

        Vo-p

        3

         

        4

        Current Consumption

        mA

        MAX. 110

        at Rated Voltage

        5

        Sound Pressure Level

        dB

        MIN. 75

        at 10cm at Rated Voltage

        6

        Coil Resistance

        Ω

        12±3

         

        7

        Operating Temperature

        -30 ~ +70

         

        8

        Storage Temperature

        -40 ~ +85

         

        9

        Dimension

        mm

        5.0 x 5.0 x H2.5

        See appearance drawing

        10

        Weight (MAX)

        gram

        0.1

         

        11

        Housing Material

         

        LCP( Black )

         

        12

        Leading Pin

         

         Tin Plated Brass(Sn)

        See appearance drawing

        13

        Environmental  
        Protection Regulation

         

         RoHS

         

         
        C. APPEARANCE DRAWING  

         
        Tol : ± 0.3      Unit: mm


        D.TESTING METHOD    
        Standard Measurement conditions
        Temperature:25±2℃  Humidity:45-65%

        Acoustic Characteristics:
        The oscillation frequency, current consumption and sound pressure are measured by the 
        measuring instruments shown below
         
        In the measuring test, buzzer is placed as follows:


        E. Typical Frequency Response Curve

        F. Recommend Driving Circuit

        The base current Ib should high enough so that it saturates the collector current of the transistor with the CB load.

        G.Soldering Condition
        (1)Recommendable reflow soldering condition is as follows
        (Reflow soldering is twice)
        Note:It is requested that reflow soldering should be executed after heat of product goes down to normal.

        Heat resistant line
        (Used when heat resistant reliability test is performed)
        (2)Manual soldering
        Manual soldering temperature 350 ℃ within 5 sec.

        H. RELIABILITY TEST

        NO.

        ITEM

        TEST CONDITION AND REQUIREMENT

        1

        High Temperature
        Test (Storage)

        After being placed in a chamber with 85 2℃ for 96 hours and then being placed in normal condition for 2 hours.
        Allowable variation of SPL after test:  10dB.

        2

        Low Temperature
        Test (Storage)

        After being Placed in a chamber with -40 2℃ for 96 hours and then being placed in normal condition for 2 hours.
        Allowable variation of SPL after test:  10dB.

        3

        Humidity Test

        After being Placed in a chamber with 90-95% R.H. at 40 2℃ for 96 hours and then being placed in normal condition for 2 hours.
        Allowable variation of SPL after test:  10dB.

        4

        Temperature Cycle
        Test

        The part shall be subjected to 5 cycles. One cycle shall be consist of:

        Allowable variation of SPL after test:  10dB.

        5

        Drop Test

        Drop on a hard wood board of 4cm thick, any directions ,6 times, at the height of 75cm .
        Allowable variation of SPL after test:  10dB.

        6

        Vibration Test

        After being applied vibration of amplitude of 1.5mm with 10 to 55 Hz band of vibration frequency to each of 3 perpendicular directions for 2 hours .
        Allowable variation of SPL after test:  10dB.

        7

        Solderability
        Test

        Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of +300 5℃ for 3 1 seconds .
        90% min. lead terminals shall be wet with solder
        (Except the edge of terminals).

        8

        Terminal Strength
        Pulling Test

        The force of 9.8N(1.0kg) is applied to each terminal in axial direction for 10 seconds.
        No visible damage and cutting off.

        TEST CONDITION.
        Standard Test Condition              :      a) Temperature : +5 ~ +35℃  b) Humidity : 45-85%        c) Pressure : 860-1060mbar 
        Judgment Test Condition             :      a) Temperature : +25 ± 2℃   b) Humidity : 60-70%         c) Pressure : 860-1060mbar 

        I. PACKING STANDARD